MD-N1 Patient Monitor for new-born
1、8.4 inch ,TFT -LCD display,touch Screen and have Screen lock button.
2、With the world's top technology that Masimo/Nellcor SPO2 and SUNTECH NIBP.
3、Unique interface and accessories specified for neonatal use only.
4、Unique neonate mode, avoid mistake and cause medical accidents.
5、The machine adopts pink, win more affinity.
6、Built-in 112MM printer for 4 channels.
7、Can option Unique rainproof "Pick and Go"accessories managerment cabinetcan well protect the sensors and wires.
8、Option ETCO2,Wired and Wireless Central Station System .
9、Up to 8 hours run time on two Li-ion batteries
Physical specifications | ||||||
Net Weight (Standard Configuration) | ||||||
Size | 300(W)×270(H)×145(D)mm | |||||
Display | ||||||
Type and size | 8.4" Color TFT | |||||
Resolution | 800*600 | |||||
Number of trace | 6 traces | |||||
Sweep speed | 12.5mm/s,25mm/s,50mm/s | |||||
Display modes | Standard display | |||||
Large-font display | ||||||
Trend coexist display | ||||||
OxyCRG dynamic view display | ||||||
Apnea analysis diagram display | ||||||
Drug does calculation | Yes | |||||
Standby mode | Yes | |||||
Opertion Environment: | ||||||
Temperature | -10ºC to 50ºC | |||||
Relative Humidity | ≤85% (noncondensing) | |||||
Atmospheric pressure | 860hPato1060 hPa | |||||
Storage/Transportation | ||||||
Temperature | -10ºC to 50ºC | |||||
Humidity | ≤93% (noncondensing) | |||||
Atmospheric pressure | 860hPato1060 hPa | |||||
Electrical | ||||||
Adapter | Input AC 100-240V 50/60Hz 1.7A Output DC 19V 3A | |||||
Vehicle power supply | DC 12-14V 5A | |||||
AC input power | 70VA | |||||
Battery | ||||||
Type | rechargable Li-ion battery | |||||
Voltage | 14.8V | |||||
Maximum number of batteries | 2 | |||||
Battery life | 7 hours with 2 battery | |||||
Charge time (Monitor switched off) | 4 Hours with 2 battery | |||||
Charge time (Monitor switched on) | 10 Hours with 2 battery | |||||
Patient Range | Neonate | |||||
Alarms | ||||||
Categories | Physical alarms and Technical alarms | |||||
Priority | High, Medium, and Low | |||||
Alarm sound levels | 0,1,2,3,4 | |||||
Notification | Visual and Audible | |||||
Pausing | 1min, 2min, 3min | |||||
Setting | Latch, Unlatch | |||||
Performance Specifications | ||||||
Data Storage | ||||||
Trend Graph | ||||||
Reviewable Parameters | HR,ST,SpO2,PR,NIBP,RR,TEMP | |||||
Resolution | 1s, 5s, 5min, 10min | |||||
Trend Data | 1 hour short trend at 1s resolution | |||||
256 hours long trend at 1min resolution | ||||||
Trend Table | ||||||
Reviewable Parameters | HR,ST,SpO2,PR,NIBP,RR,T1,T2,TD | |||||
Resolution | 1,5,10,30,60min | |||||
Trend Data | 256 Hours trend date for all parameters | |||||
NIBP measurement | 400 Groups | |||||
Reviewable Parameters | ECG,SpO2,NIBP,RESP,TEMP,HR_H>180,HR_L<60, | |||||
SpO2<90%,RR_L<10,RR_H>40, | ||||||
TEMP_H>40ºC,TEMP_L<34ºC | ||||||
ECG | ||||||
Lead type | 3-Lead or 5-Lead selectable | |||||
3 leadwire | I,II, or III | |||||
5 leadwire | I,II,III,V,AVR,AVL,AVF | |||||
Gain | ×0.25,×0.5,×1,×2,Auto | |||||
Sweep speed | 12.5mm/s, 25mm/s, 50mm/s | |||||
Standardizing voltage | 1mV marker | |||||
Bandwidth(Surgery mode) | 1-20Hz | |||||
Bandwidth(Monitoring mode) | 0.5-40Hz | |||||
Bandwidth(Diagnostic mode) | 0.05-130Hz | |||||
Multi-lead display | 6 waveforms | |||||
Lead fail | Identifies failed lead | |||||
Alarms | User-selectable upper and lower heart rate limits | |||||
ECG derived HR | ||||||
Heart Rate for Neonate/Pediatric | 15-350BPM | |||||
Heart Rate Accuracy | ±1BPM or ±1%, whichever is greater | |||||
Heart Rate Resulotion | 1BPM | |||||
Notch | 50Hz, 60Hz | |||||
ST Segment | ||||||
ST segment range | -2.0mv to 2.0mv | |||||
ST alarm range | -2.0mv to 2.0mv | |||||
ST segment accuracy | -0.8mv to 0.8mv | |||||
ST segment error | ±0.02mv | |||||
Arrythmia type | 13 types | |||||
ST analysis | 2-lead measurement | |||||
Pace | ||||||
Pace detection | Yes | |||||
Pace rejection amplitude | ±2 mV to ±700mV | |||||
Pace rejection width | 0.1ms to 2ms | |||||
Pace rejection rise time | 10µsto100µs | |||||
Temperature | ||||||
Scale | ºCelsius(C) or ºFahrenheit(F) | |||||
Probe type | YSI typs | |||||
Parameters | T1 | |||||
TD(Temperature difference) | Yes | |||||
Measurement range | 0to50ºC | |||||
Resolution | 0.1ºC | |||||
Accuracy | ±0.1ºC | |||||
Refreshing time | approximately 1S | |||||
Masimo/Nellcor SPO2 | ||||||
SpO2 | ||||||
Measurement range | 1%to100% | |||||
Resolution | 1% | |||||
Accuracy | ±2%(70%-100%); unspecified(0-69%) | |||||
Alarm range | 0to100% | |||||
Pulse Rate | ||||||
Measurement range | 20bpmto300bpm | |||||
Resolution | 1bpm | |||||
Accuracy | ±3bpm | |||||
Alarm range | 0to254bpm | |||||
SUNTECH NIBP(non-invasive blood pressure) | ||||||
Measurement technique | Oscillometric | |||||
Displayed parameters | Systolic, diastolic and MAP(mean arterial pressure) | |||||
Measurement mode | Manual, Auto,STAT | |||||
Auto cycle time | 0-4 Hours | |||||
Measurement unit | mmHg/kPa selectable | |||||
Range of Systolic pressure | Neonate:40-135mmHg | |||||
Range of mean pressure | Neonate:20-110mmHg | |||||
Range of diastolic pressure | Neonate:10-100mmHg | |||||
Accuracy | 5% | |||||
Resolution | 1mmHg | |||||
Alarms | Selectable upper and lower limits | |||||
for systolic, diastolic and mean pressure | ||||||
Over-pressure protection | Double safety protection | |||||
Respiration | ||||||
Measurement technique | RA-LL Impedance variation detection | |||||
Range | Neonate:7 to 120rpm | |||||
Apnea alarm | Yes, 10s,15s,20s,25s, no alarm selectable | |||||
Sweep speed | 6.25mm/s, 12.5mm/s, 25mm/s | |||||
Gain | 0.25, 0.5, 1, 2, 4 | |||||
Recorder | ||||||
Type | Thermal dot array | |||||
Vertical resolution | 8dot/mm | |||||
Number of waveform channels | 4(standard) | |||||
Paper width | 112mm | |||||
Paper length | 13.5m | |||||
Paper speed | 25mm/s | |||||
Standard Configuration:ECG,Masimo SPO2,SUNTECH NIBP,TEMP,PR/HR,Printer | ||||||
Optional Functions:Etco2,Wried and wireless Central station systems | ||||||
ETCO2 | ||||||
Mainstream CO2 | ||||||
Measurement range | 0-150mmHg | |||||
Accuracy | 0 to 40mmHg ±2mmHg | |||||
41 to 70mmHg ± 5% of the reading | ||||||
71 to 100mmHg ±8% of the reading | ||||||
101 to 150mmHg ±10% of the reading | ||||||
RR range | 0 to 150rpm | |||||
Accuracy | 1rpm | |||||
Response time | <60ms | |||||
Sidestream CO2 | ||||||
Measurement range | 0-150mmHg | |||||
Accuracy | 0 to 40mmHg ±2mmHg | |||||
41 to 70mmHg ± 5% of the reading | ||||||
71 to 100mmHg ±8% of the reading | ||||||
101 to 150mmHg ±10% of the reading | ||||||
Sample flowerate | 50ml/min | |||||
Accuracy | ±15% or 15ml/min,whichever is greater | |||||
Warm-up time | <1min,enter the iso accuracy mode | |||||
After 1 min,enter the full accuracy mode | ||||||
RR range | 0-120rpm | |||||
RR accuracy | ±2 rpm |