VET1800B-Veterinary DR

Products > High Frequency X-ray > VET1800B-Veterinary DR

VET1800B-Veterinary DR

VET1800B-Veterinary DR

Product Configuration List:

Name

Brand

Quantity

Remark

X ray High Frequency High Voltage Generator

FSQ30V

1 set

PLD

X ray Tube

E7239X

1 set

Canon

Collimator

XSQ30

1 set

PLD

Radiography table

SYC60

1 set

PLD

Digital Flay Panel Detector

CareView 1800CW

1 set

CareView

DR Acquisition Workstation

DRA40

1 set

PLD

Complete machine accessories

VET1800B

1 set

PLD

 

Production Parameters:

VET1800B

Content

Technical   file

Power Supply

Voltage

220V±22V

Frequency

50Hz±1Hz

Capacity

5kVA

Internal   resistance

0.4Ω

High Frequency and High Voltage Generator

Power   output

20kW

Inverter   frequency

500kHz

Radiography   tube voltage

40kV-125kV,Step1KV  

Radiography   tube current

10mA-250mA

Radiography   time

1ms-10000ms  

Control   interface

Integrated   in image workstation

Radiography   mAs

0.2~100mAs


Capacitor   charging and discharging time

20S

X ray tube assembly(E7239X)

Output   power

Big focus   42.5kW   small focus 21kW

Anode heat   capacity

100kJ(140KHU)

Maximum   heat dissipation of anode

475W(667HU/s)

Component   heat capacity

900kJ(1250KHU)

Rotating   anode speed

Minimum 2700min-1

Tube Focus:   Big Focus/Small Focus

2.0/1.0

Collimator device

(XSQ30)

Collimator   light

Halogen   lamp,24V/100W

Visible   light illumination brightness

Average   illuminance:>100Lux

Power   supply

24VAC±1.2V/6.5A

Weight

7.5KG

Radiography table

Longitudinal moving   range of bed surface

≧ 500mm

Bed transverse   movement range 

Fixed

SID

1000mm

Moving Range of   radiography  Box

Fixed

Longitudinal Moving   Range pillar

Fixed

Table height from the   ground    

700mm

Table size

1410mm×670mm

Workstation

KZT10


No case,KZT10B

Flat Panel Detector(CareView 1800L)

Image   sensor

Cesium   iodide

Pixel size

154μm

Effective pixel size

2816*2816   mm

Effective area (H x V)

434*434mm

Image transmission

Gigabit Ethernet (GbitE)

Gray scale

16bit

Spatial resolution

3.4Lp/mm

Cycle time

4-5s

Energy range

40kV to 150kV

Power input

AC 220V 50HZ

DR Collection workstation

DRA40

Basic   function

Newly build patient; newly build examination; anonymous   registration; WorkList retrieval and advanced retrieval; WorkList refresh;   WorkList information import; checklist; view image; film printing; writing   report.

Collection   function

Window width and position adjustment; 90 °   left rotation; 90 ° right rotation; horizontal   mirror; vertical mirror; image negative; clipping box; exposure parameter   setting; bulb focus switch; exposure mode selection; ionization chamber   selection; exposure actual dose value; system status indicator.

Image   viewing function

Image   zoom; local zoom; original size; Restore window size; image grid display; 90 °   left rotation; 90 ° right rotation; horizontal   mirror; text mark; line mark; angle mark; arrow mark; clipping box; rectangle   mark; circle mark; polygon mark; length correction; four corner information   display; ruler display; window width and window position adjustment; sequence   image broadcast Put; image output; silhouette function; delete image; image   enhancement; reload image; image negative.


Film   printing function

Add   image; insert image; delete image; clear image; image layout; image   selection; print format; film print settings; film format settings; add,   modify, delete printer settings.


Report   editing function

Open   report; save report; Export Report; add report; delete report; print preview;   printer settings; report template editing; image list; add report template;   delete case template.


Service   function

Daily   settings: system settings; check protocol editing; system log settings; load   user configuration.

Advanced   settings: restart system; IR settings; IR correction; problem finding;   hardware settings; backup recovery; language settings.